type: "ABB"
nummer: "ABB-0004"
abb_id: "ABB-0004"
abb_nummer: "DC02"
naam: "Datazaal"
archimate_type: "Grouping"
laag: "Datacenter"
auteur: "R. Groenewoud"
status: "Niet vermeld"
gerelateerde_adrs: ["ADR-G01", "ADR-G12"]
archimate_element: "id-33467"
archimate_grouping: "id-33467"
archimate_technology_service: "Niet gemodelleerd"
archimate_view: "id-30082"
ontwerp_paragraaf: "5.1.3"
ontwerp_link: "../../input/markdown/NDS%20Overheidsbrede%20Soevereine%20Clouddienst%20Ontwerp%20v0.9.md#decompositie-abb-datazaal"
---

# ABB-0004: Datazaal

```mermaid
%%{init: {"flowchart": {"nodeSpacing": 12, "rankSpacing": 12, "padding": 8}}}%%
flowchart TB
    %% id-33254 -> id-33467 (Grouping)
    subgraph v_id_33254["ABB: Datazaal"]
        direction TB
        %% id-33257 -> id-32047 (Facility)
        subgraph v_id_33257["Datazaal"]
            direction TB
            %% id-33275 -> id-33462 (Facility)
            v_id_33275["Fysieke Beveiliging Datazaal"]
            %% id-33266 -> id-33457 (Equipment)
            v_id_33266["Stroomverdeling Zaal"]
            %% id-33269 -> id-33458 (Equipment)
            v_id_33269["Zaalkoeling"]
            %% id-33272 -> id-33463 (Facility)
            v_id_33272["Geconditioneerde Vloer"]
            %% id-33278 -> id-33466 (Grouping)
            subgraph v_id_33278["ABB: Datacenter Module"]
                direction TB
                %% id-33281 -> id-33461 (Facility)
                v_id_33281["Datacenter Module"]
            end
            %% id-33284 -> id-33466 (Grouping)
            subgraph v_id_33284["ABB: Datacenter Module"]
                direction TB
                %% id-33287 -> id-33461 (Facility)
                v_id_33287["Datacenter Module"]
            end
        end
    end
    style v_id_33275 fill:#d6f8b8,stroke:#000000,color:#111111
    style v_id_33266 fill:#d6f8b8,stroke:#000000,color:#111111
    style v_id_33269 fill:#d6f8b8,stroke:#000000,color:#111111
    style v_id_33272 fill:#d6f8b8,stroke:#000000,color:#111111
    style v_id_33281 fill:#d6f8b8,stroke:#000000,color:#111111
    style v_id_33278 fill:#ffffff,stroke:#585858,color:#111111,stroke-dasharray:4 3
    style v_id_33287 fill:#d6f8b8,stroke:#000000,color:#111111
    style v_id_33284 fill:#ffffff,stroke:#585858,color:#111111,stroke-dasharray:4 3
    style v_id_33257 fill:#d6f8b8,stroke:#000000,color:#111111
    style v_id_33254 fill:#ffffff,stroke:#585858,color:#111111,stroke-dasharray:4 3
```

## Decompositie ABB "Datazaal"

De datazaal is een fysiek afgescheiden datacenterruimte met voorzieningen zoals stroomvoorziening en koeling. De datazaal wordt geëxploiteerd door de aanbieder van de NDS Clouddienst.

![Figuur 5‑4 Decompositie ABB Datazaal](<../../input/markdown/media/media/image19.png>)

Figuur 5‑4 Decompositie ABB Datazaal

Samenvatting uitgangspunten, architectuurkeuzes en aandachtspunten:

- Wholesale-model: de aanbieder NDS Cloud huurt een lege datazaal;

- De aanbieder datazaal zorgt ook voor fysieke toegangsbeveiliging;

- De aanbieder NDS Cloud zorgt voor hardware;

- Fit-out: extra datazaal als 1e datazaal 80% vol is;

- De aanbieder NDS Cloud bedingt opties voor datacenterruimte en stroomgebruik.