type: "ABB"
nummer: "ABB-0107"
abb_id: "ABB-0107"
abb_nummer: "NE01"
naam: "Underlay Network"
archimate_type: "Grouping"
laag: "Netwerk"
auteur: "R. Groenewoud"
status: "Niet vermeld"
gerelateerde_adrs: ["ADR-C08", "ADR-C60", "ADR-G56", "ADR-G65"]
archimate_element: "id-30474"
archimate_grouping: "id-30474"
archimate_technology_service: ["id-30476"]
archimate_view: "id-29927"
ontwerp_paragraaf: "5.2.3"
ontwerp_link: "../../input/markdown/NDS%20Overheidsbrede%20Soevereine%20Clouddienst%20Ontwerp%20v0.9.md#positionering-abb-underlay-network"
ontwerp_paragrafen: ["5.2.3", "5.4.1", "5.4.3"]
ontwerp_links:
  - "../../input/markdown/NDS%20Overheidsbrede%20Soevereine%20Clouddienst%20Ontwerp%20v0.9.md#positionering-abb-underlay-network"
  - "../../input/markdown/NDS%20Overheidsbrede%20Soevereine%20Clouddienst%20Ontwerp%20v0.9.md#positionering-abb-management-cluster"
  - "../../input/markdown/NDS%20Overheidsbrede%20Soevereine%20Clouddienst%20Ontwerp%20v0.9.md#positionering-abb-tenant-cluster"
---

# ABB-0107: Underlay Network

```mermaid
%%{init: {"flowchart": {"nodeSpacing": 20, "rankSpacing": 40, "padding": 12, "subGraphTitleMargin": {"top": 0, "bottom": 24}}}}%%
flowchart TB
    %% id-31481 -> id-31417 (Grouping)
    subgraph v_id_31481["ABB: Firewall"]
        direction TB
        %% id-31482 -> id-30620 (TechnologyService)
        v_id_31482["Firewall"]
    end
    %% id-31486 -> id-31420 (Grouping)
    subgraph v_id_31486["ABB: IDS/IPS"]
        direction TB
        %% id-31487 -> id-30602 (TechnologyService)
        v_id_31487["IDS/IPS"]
    end
    %% id-31497 -> id-31498 (Grouping)
    subgraph v_id_31497["ABB: Forward &amp; Reverse Proxy"]
        direction TB
        %% id-31499 -> id-30615 (TechnologyService)
        v_id_31499["Forward &amp; Reverse Proxy"]
    end
    %% id-31490 -> id-31491 (Grouping)
    subgraph v_id_31490["ABB: Loadbalancing"]
        direction TB
        %% id-31492 -> id-30605 (TechnologyService)
        v_id_31492["Loadbalancing"]
    end
    %% id-31493 -> id-31494 (Grouping)
    subgraph v_id_31493["ABB: TLS Inspection"]
        direction TB
        %% id-31495 -> id-30604 (TechnologyService)
        v_id_31495["TLS Inspection"]
    end
    %% id-31501 -> id-30474 (Grouping)
    subgraph v_id_31501["ABB: Underlay Network"]
        direction TB
        %% id-31502 -> id-30476 (TechnologyService)
        v_id_31502["Underlay Network"]
    end
    %% id-31503 -> id-31468 (Grouping)
    subgraph v_id_31503["ABB: Bare-Metal Switching"]
        direction TB
        %% id-31504 -> id-30663 (TechnologyService)
        v_id_31504["Bare-Metal Switching"]
    end
    v_id_31502 -->|Serving| v_id_31482
    v_id_31502 -->|Serving| v_id_31487
    v_id_31502 -->|Serving| v_id_31499
    v_id_31495 -->|Serving| v_id_31499
    v_id_31495 -->|Serving| v_id_31492
    v_id_31502 -->|Serving| v_id_31492
    v_id_31504 -->|Serving| v_id_31502
    style v_id_31482 fill:#d6f8b8,stroke:#000000,color:#111111
    style v_id_31481 fill:#ffffff,stroke:#585858,color:#111111,stroke-dasharray:4 3
    style v_id_31487 fill:#d6f8b8,stroke:#000000,color:#111111
    style v_id_31486 fill:#ffffff,stroke:#585858,color:#111111,stroke-dasharray:4 3
    style v_id_31499 fill:#d6f8b8,stroke:#000000,color:#111111
    style v_id_31497 fill:#ffffff,stroke:#585858,color:#111111,stroke-dasharray:4 3
    style v_id_31492 fill:#d6f8b8,stroke:#000000,color:#111111
    style v_id_31490 fill:#ffffff,stroke:#585858,color:#111111,stroke-dasharray:4 3
    style v_id_31495 fill:#d6f8b8,stroke:#000000,color:#111111
    style v_id_31493 fill:#ffffff,stroke:#585858,color:#111111,stroke-dasharray:4 3
    style v_id_31502 fill:#d6f8b8,stroke:#000000,color:#111111
    style v_id_31501 fill:#ffffff,stroke:#585858,color:#111111,stroke-dasharray:4 3
    style v_id_31504 fill:#d6f8b8,stroke:#000000,color:#111111
    style v_id_31503 fill:#ffffff,stroke:#585858,color:#111111,stroke-dasharray:4 3
```

## Positionering ABB “Underlay Network”

Binnen de gehuurde datazalen wordt netwerkconnectiviteit gerealiseerd met meerdere gescheiden OSI RM Laag-3 routeringsdomeinen. De benodigde netwerkswitches kunnen hiervoor softwarematig als bare-metal worden toegewezen.

![Figuur 5‑7 Positionering ABB Underlay Network](<../../input/markdown/media/media/image24.svg>)

Samenvatting uitgangspunten, architectuurkeuzes en aandachtspunten:

- Het Underlay netwerk biedt basisconnectiviteit voor het overlay netwerk *(niet expliciet gemodelleerd)* dat connectiviteit biedt tussen individuele Kubernetes Pods en typisch via de CNI-interface ontsloten wordt.

## Positionering ABB "Management Cluster"

De technologiestack bestaat uit één Kubernetes managementcluster die gebruikt wordt voor het beheer van meerdere tenantclusters.

![Figuur 5‑14 Positionering ABB Management Cluster](<../../input/markdown/media/media/image37.svg>)

## Positionering ABB "Tenant Cluster"

Elk Tenant Cluster bestaat uit Worker Nodes met eigen hardware. De Kubernetes control plan van elk Tenant Cluster maakt wel gebruik van gedeelde hardware (Hosted Control Plane).

![Figuur 5‑16 Positionering ABB Tenant Cluster](<../../input/markdown/media/media/image41.svg>)

Samenvatting uitgangspunten, architectuurkeuzes en aandachtspunten:

- De afnemer kan één of meerdere tenantclusters afnemen die zowel onderling als van tenantclusters van andere afnemers fysiek gescheiden zijn;

- Elke tenantcluster kan logisch verder opgedeeld worden in projecten die elk weer bestaan uit Kubernetes namespaces.